Cross Technologies 2016-03A Manual de instrucciones Pagina 1

Busca en linea o descarga Manual de instrucciones para No Cross Technologies 2016-03A. Cross Technologies 2016-03A Instruction manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 18
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Instruction Manual
Model 2016-03A
L-Band Downconverter
November 2008 Rev A
C
ROSS
T
ECHNOLOGIES, INC.
MODEL 2016
D
O
WN
CO
NVERTER
F = 1525 G = +25.0
ALARM
POWER
REMO TE
MENU
EXECUTE
Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc.,
but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc.
for purposes of operating the equipment.
When ordering parts from Cross Technologies, Inc., be sure to include the equipment
model number, equipment serial number, and a description of the part.
CROSS TECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB www.crosstechnologies.com
Vista de pagina 0
1 2 3 4 5 6 ... 17 18

Indice de contenidos

Pagina 1 - Model 2016-03A

Instruction Manual Model 2016-03A L-Band Downconverter November 2008 Rev A CROSS TECHNOLOGIES, INC.MODEL 2016 DOWNCONVE

Pagina 2

2.2 Rear Panel Input/Output Signals - Figure 2.2 shows the input and output connectors on the rear panel.ACGNDJ18J2RF IN 10 MHZ REFOUTPUTAC - POWER I

Pagina 3 - CROSS TECHNOLOGIES INC

2.3 Front Panel Controls and Indicators - The following are the front panel controls and indicators.MENUEXECUTEREMOTEALARM POWERLCD DISPLAYDisplay sh

Pagina 4

2.4 Operation2.4.1 Installing and Operating the 2016-03A Downconverter1. Connect a -20 dBm to -70 dBm signal to RF IN, J2 (Figure 2.2)2. Connect the

Pagina 5

2.5 Menu Settings2.5.1 Functions - This section describes operation of the front panel controls. There are three operator switches, the LCD displ

Pagina 6 - C) Status Requests

2.5.2 Power On SettingsNOTE: THE LAST STATUS OF A UNIT IS RETAINED EVEN WHEN POWER IS REMOVED. WHEN POWER IS RESTORED, THE UNIT WILL RETURN TO IT&ap

Pagina 7

2.5.4 Frequency ChangesAt any time during the modification process, if you have made a mistake and do not wish to save the changes you have made, do

Pagina 8

2.5.5 Gain ChangesWhen you get to this menu note that the gain changes will be made as you make them but if you do not wish to save the changes you h

Pagina 9

2.5.5 Alarm IndicationsAn alarm condition for will occur if any local oscillator phase lock loop (PLL) comes out of lock. The Mute LED will light if

Pagina 10 - Interface: DB-9 Male

CROSS TECHNOLOGIES, INC.6170 Shiloh RoadAlpharetta, Georgia 30005(770) 886-8005FAX (770) 886-7964Toll Free 888-900-5588WEB www.crosstechnologies.com E

Pagina 11 - F=1525 G=+25.0

INSTRUCTION MANUALMODEL 2016-03A Downconverter TABLE OF CONTENTS PAGEWarranty 21.0 General 31.1 Equipment Description 31.2 Technical Chara

Pagina 12

MODEL 2016-03A L-band Downconverter1.0 General1.1 Equipment DescriptionThe 2016-03A L-band Downconverter converts 950-1525 MHz to 70 (±18) MHz in 1

Pagina 13

1.2 Technical CharacteristicsTABLE 1.0 2016-03A Downconverter Specifications*Input Characteristics Impedance/Return Loss 75/12 dB (see TABLE 2.2

Pagina 14 - F=1350 G=+25.0

1.3 Monitor and Control InterfaceA) Remote serial interfaceProtocol: RS-232C, 9600 baud rate, no parity, 8 data bits, 1 start bit, and 1 stop bit.(RS

Pagina 15

C) Status Requests - Table 1.2 lists the status requests for the 2016-03A and briefly describes them.* PLEASE NOTE: The two character {aa}(00-31) pref

Pagina 16

B) Commands - Table 1.1 lists the commands for the 2016-03A and briefly describes them. After a command is sent the 2016-03A sends a return “>” ind

Pagina 17 - 2.5.5 Alarm Indications

1.4 Use InformationA. Elevated operating ambient temperature - if installed in a closed or multi-unit rack assembly, the operating ambient temperatur

Pagina 18 - CROSS TECHNOLOGIES, INC

2.0 Installation2.1 Mechanical - The 2016-03A consists of one RF/Controller PCB housed in a 1 RU (1 3/4 inch high) by 16 inch deep chassis. A switch

Comentarios a estos manuales