(Status Request continued from page 7...)
TABLE 1.1 2415-x02 Statuus
Status Requests Coontinued
TABLE 1.1 2415-x02 Status Requests Continued
Command Syntax* Description
Get IF Frequency {aa*iSY} Returns {*iSYx} where :
(Option W160/70) • i = 1, 2, 3 or 4...
• x = 0 for 70 MHz IF, 1 for 160 MHz IF
Get IP address {aaSi} Returns {Sixxx.xxx.xxx.xxx} where :
(If Ethernet Option, W8, W18, or W
8, enabled) • xxx.xxx.xxx.xxx = IP address
Get subnet mask {aaSs} Returns {Ssxxx.xxx.xxx.xxx} where :
(If Ethernet Option, W8, W18, or W
8, enabled) • xxx.xxx.xxx.xxx = subnet mask
Get channel base parms {aa*iS1} Returns {*iS1tfffffffgggha} where :
• i = 1, 2, 3 or 4 designating the channel number
• t=channel type: 0 for unused;
1 for upconverter; 2 for downconverter
• fffffff = frequency in KHz
• ggg = gain to nearest 1.0 dB (e.g., +25 = 25 dB)
• h = spectrum output: 0 for non-invert; 1 for invert
• a = alarm: 0 for alarm off; 1 for alarm on
Get alarm status {aaSA} Returns {SAabcd} where:
• a=channel 1 alarm state (0 for alarm off; 1 for alarm on)
• b=channel 2 alarm state (0 for alarm off; 1 for alarm on)
• c=channel 3 alarm state (0 for alarm off; 1 for alarm on)
• d=channel 4 alarm state (0 for alarm off; 1 for alarm on)
Get product/model info {aaSV} Returns {SV2416-x02xxxver5.00} where:
• 2416-x02 = product model
• xxx = list of options, if any
•"ver"=separates model & options from firmware version
• 5.00 = firmware version
(C) Commands
2415-x02 Manual, Rev. A Page 8 02/25/15